2013 Household Energy Survey
free website design templates
Survey by Robbins still in progress - open to new data submittals.  Results as of 5 Apr 2017
ID RESIDENTSFLOOR SF
PER
RES
ENERGY
FEATURES
COUNTY
+
STATE
$/PERSON $/SF kBTU kBTU/$kBTU PER SF (EUI)PER SF COMPARED TO 2001 USA AVG BTUs PER SF PER DD mBTU PER PERSONPER PERSON COMPARED TO 2001 USA AVGkBTUs PER PERSON PER DDAVG CO2 LBS PER kBTUAVG CO2 LBS PER PERSON PER DAYAVG PURCHASED WATER GALLONS PER PERSON PER DAY
BRNW

22474ABEFGHLPSTWBoone KY950.140.38582913111.825%1.929.181%4.70.5947
BRSW3740BEFHPTAnderson KY336.590.45366903616.535%2.712.234%2.00.592033
CALM (b)41194BEFGHKLPSTHamilton OH440.240.371085506222.749%3.727.175%4.40.171351
CLKE (b)2.251052DEFGHIHamilton OH1035.110.981372295958.0124%9.361.0169%9.80.233838
FRHR21311EFGHLHamilton OH661.530.50412383115.734%2.520.657%3.30.593336
GETE (a)3.5874BEFGHPSTHamilton OH452.620.52594863819.542%3.117.047%2.70.331534
GETM12220GILHamilton OH1317.640.591048208047.2101%7.6104.8291%16.80.164543
RAIK2945CDEFHILSTBrown OH972.001.03553072829.363%4.727.777%4.40.594415
ROSG (a)22000BDEFGHLSTButler OH1093.150.55571812614.331%2.328.679%4.60.574577
ROSJ (b)21050ABCDEFHILPSTVKenton KY558.530.53476604322.749%3.623.866%3.80.362334
TEOJ21700BEFLPHamilton OH9881629.162%4.749.4137%7.90.283813
VOTC4900ABCEFHILMPSTVClermont OH360.000.4015314910642.591%6.838.3106%6.20.151632
WHEJ (a)21602DEFGHLPSTButler OH825.050.52675174121.145%3.433.894%5.40.333071
See Top Line In Rating Gauge See Bottom Line In Rating Gauge
Mobirise

NOTES:

ID: lastname 1st two and last one initial + firstname 1st initial

(a) living in newer homes designed by Robbins

(b) living in homes with additions, remodelling and/or altered operations after consultation and/or redesign by Robbins 

"DD" in all above references means "degree-days", which are a numerical way of representing accummulated daily differences between 65F and average outdoor temperature.  In this survey "DD" refers to the sum of heating and cooling degree-days.   For 2013, heating degree-days (HDD) for Cincinnati (CVG Airport) were 5066, cooling degree-days (CDD) were 1159.  HDDs for Lexington KY (BlueGrass Airport) were 4827, CDDs were 1283.  HDDs for Louisville (Standiford Airport) were 4438, CDDs were 1645. 

John F Robbins, CEM / CSDP 
859.363.0376
john@johnfrobbins.com
www.johnfrobbins.com
3519 Moffett Rd
Morning View, KY USA
41063-8748

Mobirise

John F. Robbins is also at LinkedIn and Facebook